RIHSA와 131I-Hippuran으로 측정한 심박출량의 비교 (A Comparative Study of the Cardiac Output Measurement with RIHSA and 131I-Hippuran )
()
Author 이안기(A. K. Lee),길광수(K. S. Kil),박진영(J. Y. Park),김동섭(D. S. Kim),김정일(J I Kim),고창순(C . S. Koh),
Affiliation
Abstract

Repeated measurement of cardiac output in the same 11 normal individuals were done with 131I-Hippuran and RIHSA. Following results were obtained. 1) The cardiac output measured with RIHSA was 6750¡¾866ml/min. 2) The cardiac output measured with 131I-Hippuran was 5940¡¾764ml/min. 3) The relative value of cardiac output measured with 131I-Hippuran to that measured with RIHSA was 88 percent, and a statistical significance was found present in the difference.