대한핵의학회지 (1967년~2009년)
대한핵의학회지 1996;30(4)570~6
증례 : 아급성 뇌경색 환자에서 99mTC - HMPAO 및 99mTc - ECD 뇌 SPECT : 증례보고 ( Brain SPECT Using 99mTc - HMPAO and 99mTc - ECD in Subacute Cerebral Infarction : Case Report )
()
Author 안병철(Byeong Cheol Ahn),이동수(Dong Soo Lee),윤병우(Byung Woo Yoon),소영(Young So),정준기(June Key Jung),이명철(Myung Chul Lee),고창순(Chang Soon Koh),
Affiliation
Abstract

For brain perfusion SPECT imaging, Tc-99m-HMPAO and Tc- 99m-ECD are commonly used. Although these two tracers usually show similar distribution, it is well known that discrepant finding might be noted between Tc-99m- HMPAO and Tc-99m-ECD imaging in some conditions. Luxury perfusion(perfusion/metabolism mismatch) is one of the examples and could be observed in subacute cerebral infarction. We report a case of subacute cerebral infarction that revealed luxury perfusion. Increased perfusion was found in Tc-99m-HMPAO SPECT and perfusion defect was found in Tc-99m-ECD SPECT. We found 1arge area of mismatch with a consecutive acquisition- subtraction method. Crossed cerebellar diaschisis was observed in both SPECT images.

Keyword Luxury perfusion, 99mTc-HMPAO, 99mTc-ECD, SPECT