섬광근접측정법 ( Scintillation Proximity Assay )
()
Author 최창운(Chang Woon Choi),
Affiliation
Abstract

Scintillation proximity assay (SPA) is a unique type of radioimmunoassay and makes it possible to use radioisotopes for monitoring binding reactions continuously without separation procedure. Microbeads containing a fluorophor are covalently linked to antibody or receptor. When a radiolabeled antigen or ligand is added it binds to the beads and the emitted short range electrons, excite the fluorophor in the beads. The light emitted can be measured in a scintillation counter. 3H or 125I has been used for SPA. The sensitivities achieved with SPA are comparable to the sensitivities of other procedures. SPA is applicable to immunology, receptor binding, monitoring interactions of biomolecules and study for the kinetics of interaction between receptors and ligands.

Keyword Scintillation proximity assay , Radioimmunoassay