대한핵의학회지 (1967년~2009년)
대한핵의학회지 2004;38(3)218~224
좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 Tl-201 재분포 SPECT와 휴식기 N-13 Ammonia PET: 분절 비교 및 불일치 분석
(Tl-201 Redistribution SPECT and N-13 Ammonia PET Images in Patients with Old Myocardial Infarction and Left Ventricular Dysfunction: Segmental Comparison and Discordance Analysis)
Author 최준영,이경한,김영환,이은정,정현우,이수진,이상훈1,김병태,
Joon Young Choi, M.D., Kyung-Han Lee, M.D., Young Hwan Kim, M.D., Eun Jeong Lee, M.D., Hyun Woo Chung, M.D., Su Jin Lee, M.D., Sang Hoon Lee, M.D.1 and Byung-Tae Kim, M.D.
Affiliation 성균관대학교 의과대학 삼성서울병원 핵의학과, 순환기내과1
Department of Nuclear Medicine and Cardiovascular Institute1, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
Abstract

We compared rest perfusion PET with redistribution perfusion SPECT to investigate the concordant rate between PET and SPECT images and analyze the discordant pattern. Materials and Methods: Rest N-13 ammonia and F-18 FDG PET were performed on 18 patients with old myocardial infarction and left ventricular dysfunction whose dipyridamole - 4hr redistribution Tl-201 SPECT showed one or more severe fixed defects. Regional perfusion and metabolism were evaluated visually and quantitatively with 5-segment myocardial model. Results: There were high concordant rate in uptake pattern (80/90 segments, 88.9%) and high correlation coefficient on quantitative analysis (R=0.81, p<0.001) between redistrubution Tl-201 SPECT and N-13 ammonia PET images. Nine of 18 patients had SPECT-PET concordant pattern (Group I). Ten segments (9 in inferior wall, 1 in apex) from the remaining 9 patients showed SPECT-PET discordant pattern with abnormal Tl-201 defect and near normal N-13 ammonia uptake (Group II). The diastolic and systolic left ventricular dimensions were significantly increased in Group II compared to those of Group I. When attenuation uncorrected N-13 ammonia PET images were reconstructed in Group II, it resulted in PET images with severe inferior wall defects nearly identical to those seen in redistribution Tl-201 SPECT images. Conclusion: Redistribution Tl-201 SPECT images showed high concordant rate and correlation with rest N-13 ammonia PET images. Most of discordant segments had fixed thallium defects in inferior wall with nearly normal N-13 ammonia uptake, which may result from severe left ventricular dilatation and attenuation by the left hemidiaphragm and cardiac blood pool. (Korean J Nucl Med 38(3):218-224, 2004)

Keyword Myocardial infarction, Myocardial SPECT, Myocardial PET, Tl-201, N-13 ammonia, Attenuation artifact
Full text Article 3803218.pdf 3803218.pdf
(03121)서울시 종로구 지봉로 29 금호팔레스빌딩 1705호
TEL : 02-745-2040 FAX : 02-745-3833 E-mail : ksnm@ksnm.or.kr
Copyright 2012 by The Korean Society of Nuclear Medicine(KSNM)