대한핵의학회지 (1967년~2009년)
대한핵의학회지 2005;39(6)464~472
부채살 SPECT 데이터를 위한 정칙화된 기댓값 최대화 재구성기법 개발
(Development of Regularized Expectation Maximization Algorithms for Fan-Beam SPECT Data)
Author 김수미1,이재성1,이수진2,김경민3,이동수1,
Soo Mee Kim1, Jae Sung Lee1, Soo-Jin Lee2, Kyeong Min Kim3, Dong Soo Lee1
Affiliation 서울대학교 의과대학 핵의학교실 및 방사선응용생명과학 협동과정1, 배재대학교 전자공학과2, 원자력의학원 핵의학과3
Department of Nuclear Medicine and Interdisciplinary Program in Radiation Applied Life Science Major1, Seoul National University College of Medicine, Seoul, Korea Department of Electronic Engineering2, Paichai University, Daejeon, Korea, Department of Nuc
Abstract

Purpose: SPECT using a fan-beam collimator improves spatial resolution and sensitivity. For the reconstruction from fan-beam projections, it is necessary to implement direct fan-beam reconstruction methods without transforming the data into the parallel geometry. In this study, various fan-beam reconstruction algorithms were implemented and their performances were compared. Materials and Methods: The projector for fan-beam SPECT was implemented using a ray-tracing method. The direct reconstruction algorithms implemented for fan-beam projection data were FBP (filtered backprojection), EM (expectation maximization), OS-EM (ordered subsets EM) and MAP-EM OSL (maximum a posteriori EM using the one-step late method) with membrane and thin-plate models as priors. For comparison, the fan-beam projection data were also rebinned into the parallel data using various interpolation methods, such as the nearest neighbor, bilinear and bicubic interpolations, and reconstructed using the conventional EM algorithm for parallel data. Noiseless and noisy projection data from the digital Hoffman brain and Shepp/Logan phantoms were reconstructed using the above algorithms. The reconstructed images were compared in terms of a percent error metric. Results: For the fan-beam data with Poisson noise, the MAP-EM OSL algorithm with the thin-plate prior showed the best result in both percent error and stability. Bilinear interpolation was the most effective method for rebinning from the fan-beam to parallel geometry when the accuracy and computation load were considered. Direct fan-beam EM econstructions were more accurate than the standard EM reconstructions obtained from rebinned parallel data. Conclusion: Direct fan-beam reconstruction algorithms were implemented, which provided significantly improved reconstructions.(Korean J Nucl Med 39(6):464-472, 2005)

Keyword Reconstruction, Fan-beam projection data, FBP, EM, OSL, Ray-tracing method
Full text Article 39060464.pdf 39060464.pdf
(03121)서울시 종로구 지봉로 29 금호팔레스빌딩 1705호
TEL : 02-745-2040 FAX : 02-745-3833 E-mail : ksnm@ksnm.or.kr
Copyright 2012 by The Korean Society of Nuclear Medicine(KSNM)