대한핵의학회지 (1967년~2009년)
Nucl Med Mol Imaging 2009;43(6)513~518
심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성
(Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT)
Author 공은정1, 조인호1, 강원준2, 김성민3, 원경숙4, 임석태5, 황경훈6, 이병일7, 범희승7,
Eun Jung Kong M.D.1, Ihn Ho Cho M.D.1, Won Jun Kang M.D.2, Seong Min Kim M.D.3, Kyoung Sook Won M.D.4, Seok Tae Lim M.D.5, Kyung Hoon Hwang M.D.6, Byeong Il Lee Ph.D.7, and Hee Seung Bom M.D.7
Affiliation 영남대학교병원 핵의학과1, 연세대학교병원 핵의학과2, 충남대학교병원 핵의학과3, 계명대학교병원 핵의학과4, 전북대학교병원 핵의학과5, 가천의대 길병원 핵의학과6, 전남대학교병원 핵의학과7
1Department of Nuclear Medicine, Yeungnam University Hospital, Daegu, Korea; 2Department of Nuclear Medicine, Yonsei University Hospital, Seoul, Korea; 3Department of Nuclear Medicine, Chungnam National University Medical School and Hospital, Daejeon, Kor
Abstract

Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morpho- anatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: 63.3¡¾10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Keyword SPECT, SPECT/CT, fusion imaging, coronary artery disease
Full text Article 4306513518.pdf 4306513518.pdf
(03121)서울시 종로구 지봉로 29 금호팔레스빌딩 1705호
TEL : 02-745-2040 FAX : 02-745-3833 E-mail : ksnm@ksnm.or.kr