대한핵의학회지 (1967년~2009년)
대한핵의학회지 1986;20(2)39~7
관상동맥질환에서 Gated Blood Pool Scan 을 이용한 좌심실 확장기능의 분석 ( Analysis of Left Ventricular Diastolic Function in Coronary Artery Disease with Gated Blood Pool Scan )
()
Author 최창운(Chang Woon Choi),임상무(Sang Moo Lim),정준기(June Key Chung),이명철(Myung Chul Lee),박영배(Young Bae Park),서정돈(Joung Don Seo),이영우(Young Woo Lee),고창순(Chang Soon Koh),
Affiliation
Abstract

Resting gated blood pool scan was used to derive left ventricular functional changes in norrnals (N=13, mean age=43) and in patients with coronary artery disease (N=50, mean age=53). Peak filling rates, average filling rates, and ejection fractions were significantly depressed m coronary artery disease. (p < 0.0005, each other). And in coronary artery disease with normal ejection fraction (N = 21), peak filling rates and average filling rates were depressed also, and peak filling rates of coronary artery disease with normal ejection fraction were abnormal in 61.2% and average fillin rates were abnormal in 71.4/. It appears that (1) resting peak filling rates and average filling rates were sensitive and easily obtainable pararneters of the diastolic dysfunction assosiated with coronary artery disease, (2) a significant proportion of coronary artery disease patients without any evidence of abnormal systolic function have depressed resting peak filling rates and average filling rates of the left ventricle.

Keyword
Full text Article 28500677.pdf 28500677.pdf
(03121)서울시 종로구 지봉로 29 금호팔레스빌딩 1705호
TEL : 02-745-2040 FAX : 02-745-3833 E-mail : ksnm@ksnm.or.kr