원저 : 간신티그라피에서 Digital Image와 Analogue Image 판독의 비교 ( Comparison of Interpretations between Digital Image and Analogue Image in Liver Scintigraphy ) () |
Author |
최윤호(Yoon Ho Choi),이범우(Bum Woo Lee),문대혁(Dae Hyuk Moon),정준기(June Key Chung),이명철(Myung Chul Lee),고창순(Chang Soon Koh),박석건(Seok Gun Park),이명혜(Myung Hae Lee), |
|
Affiliation |
|
Abstract |
The authors studied to evaluate the difference of the
diagnostic performance between reading from digital
image on the video CRT of PACS (Picture Archiving and
Communication System) and from analogue image of
conventional film mode. We compared interpretative
accuracy of above two rcading modes by having two
observers read a series of liver scintigrams. Images
were read once from film and a second time from video
CRT of elementary PACS. The cinncordance rate of
interpretation of the two mocles was in the range from
61.0% to 93.2%. The diagnostic accuracies of digital
image reading and analogue image reading were 72 9,%
and 74.6% respectively in one observer, and 72.9% and
76 3% in another one No significant difference in
interpretative accuracy could he found between two
modes of reading. |
Keyword |
|
Full text Article |
28500949.pdf
|
|
|