대한핵의학회지 (1967년~2009년)
Nucl Med Mol Imaging 2008;42(5)354~361
관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교
(Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPECT in Coronary Artery Disease)
Author 공은정, 조인호, 천경아, 원규장1, 이형우1, 박종선1, 신동구1, 김영조1, 심봉섭1,
Eun-Jung Kong, M.D., Ihn-Ho Cho, M.D., Kyung-Ah Chun, M.D., Kyu-Chang Won, M.D.1,Hyung-Woo Lee M.D.1, Jeong-Sun Park, M.D.1, Dong-Gu Shin, M.D.1,Young-Jo Kim, M.D.1, and Bong-Seop Shim, M.D.1
Affiliation 영남대학교 의과대학 핵의학교실, 내과학교실1
Department of Nuclear Medicine and Internal Medicine1 Yeungnam University, College of Medicine, Daegu, Korea
Abstract

Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : 63¡¾11 years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/ 89% vs MPS: 65%/ 82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability. (Nucl Med Mol Imaging 2008;42(5):354-361)

Keyword N-13 ammonia, PET/CT, SPECT, myocardial perfusion, myocardial ischemia
Full text Article 450504.pdf 450504.pdf
(03121)서울시 종로구 지봉로 29 금호팔레스빌딩 1705호
TEL : 02-745-2040 FAX : 02-745-3833 E-mail : ksnm@ksnm.or.kr
Copyright 2012 by The Korean Society of Nuclear Medicine(KSNM)