대한핵의학회지 (1967년~2009년)
Nucl Med Mol Imaging 2009;43(2)129~136
분화 갑상선암의 추적 관찰에서 진단적 I-123 전신 스캔의 최적 영상 시점: 동일 환자에서 6시간과 24시간 영상의 비교
(Optimal Imaging Time for Diagnostic I-123 Whole Body Scan in the Follow-up of Patients with Differentiated Thyroid Cancer: Comparison between 6- and 24-Hour Images of the Same Subjects)
Author 이홍제, 이상우, 송봉일, 강성민, 서지형, 유정수, 안병철, 이재태,
Hong Je Lee, M.D., Sang-Woo Lee, M.D., Bong Il Song, M.D., Sung-Min Kang, M.D., Ji-Hyoung Seo, M.D., Jeongsoo Yoo, Ph.D., Byeong-Cheol Ahn, M.D., and Jaetae Lee, M.D.
Affiliation 경북대학교 의학전문대학원 핵의학교실
Department of Nuclear Medicine, Kyungpook National University School of Medicine, Daegu, Korea
Abstract

Purpose: To determine optimal imaging time for diagnostic I-123 whole body scan in the follow-up of patients with differentiated thyroid cancer (DTC), we compared the image quality of 6- and 24-hour images of the same subjects. Materials and Methods: Four hundred ninety-eight patients (M:F=55:443, Age 47.6¡¾12.9 years) with DTC who had undergone total thyroidectomy and I-131 ablation therapy underwent diagnostic whole body scanning 6 hour and 24 hour after oral ingestion of 185 MBq (5 mCi) of I-123. Serum thyroglobulin measurement and ultrasonography of the neck were performed at the time of imaging. In 40 patients underwent additional I-131 therapy, post-therapy I-131 images were obtained and compared with diagnostic I-123 images. Results: In 440 patients (88.4%), 6- and 24-hour diagnostic I-123 images were concordant, and 58 patients (11.6%) showed discordant findings. Among 58 discordant patients, 31 patients showed abnormal tracer uptake on only 6-hour image, which turned out false-positive findings in all cases. In 12 patients with positive findings on only 24-hour image, remnant thyroid tissue (4 patients) and cervical lymph node metastasis (3 patients) were presented. Among 40 patients underwent additional I-131 therapy, 6-hour and 24-hour images were discordant in 13 patients. All 5 patients with abnormal uptake on only 6-hour image revealed false-positive results, whereas most of 24-hour images were concordant with post-therapy I-131 images. Conclusion: I-123 imaging at 24-hour could reduce false-positive findings and improve diagnostic accuracy, compared with 6-hour image in the follow-up of patient with DTC. (Nucl Med Mol Imaging 2009;43(2):129-136)

Keyword Differentiated thyroid cancer, diagnostic I-123 scan, post-therapy I-131 scan